Size: | |
---|---|
Availability: | |
Quantity: | |
Why do you need a control cabinet cooling air conditioner?
With the acceleration of the industrialization process and the improvement of the automation of various equipments, the application of precision electronic components such as inverters, servo amplifiers, and PLC controllers has become more and more widespread. The above equipment will generate heat during normal operation. If this part of the heat is not transferred in time, it will cause the temperature inside the control cabinet to rise. Once the temperature inside the cabinet exceeds 45 °C (the air temperature in the cabinet exceeds 40 °C, due to the heat island) The effect, the temperature of the surface of the heating component on the circuit board will exceed 55 ° C) will affect the stability of the gas equipment, and it is prone to accidents of burning circuit board components.
Power supply is -48VDC, mainly used for telecommunication outdoor cabinets, battery cabinet etc. 1. A reliable, high efficient and long lifetime cooling solution for telecom outdoor cabinet 2. Intelligent controller built in for having remote control, alarming output. 3. The fan speed can be regulated with low noise, high efficiency operation. |
Product Detail
Cooling Capacity | Product Model | P/N | Mounting method | Dimension | Dimension (without flange) | IP | Noise | Certification |
200W/K | LCE200ED | G1007 | Semi-embedded | 569*240*1297 | 518*240*1246 | 55 | 65 | CE |
Why do you need a control cabinet cooling air conditioner?
With the acceleration of the industrialization process and the improvement of the automation of various equipments, the application of precision electronic components such as inverters, servo amplifiers, and PLC controllers has become more and more widespread. The above equipment will generate heat during normal operation. If this part of the heat is not transferred in time, it will cause the temperature inside the control cabinet to rise. Once the temperature inside the cabinet exceeds 45 °C (the air temperature in the cabinet exceeds 40 °C, due to the heat island) The effect, the temperature of the surface of the heating component on the circuit board will exceed 55 ° C) will affect the stability of the gas equipment, and it is prone to accidents of burning circuit board components.
Power supply is -48VDC, mainly used for telecommunication outdoor cabinets, battery cabinet etc. 1. A reliable, high efficient and long lifetime cooling solution for telecom outdoor cabinet 2. Intelligent controller built in for having remote control, alarming output. 3. The fan speed can be regulated with low noise, high efficiency operation. |
Product Detail
Cooling Capacity | Product Model | P/N | Mounting method | Dimension | Dimension (without flange) | IP | Noise | Certification |
200W/K | LCE200ED | G1007 | Semi-embedded | 569*240*1297 | 518*240*1246 | 55 | 65 | CE |
Realize telemetry, remote signaling and remote adjustment, and realize multiple automatic protection and comprehensive fault self diagnosis function;
Exquisite workmanship and high-quality international famous brand accessories ensure that the products are more stable and reliable;
Multiple protection functions, RS485 interface (MODBUS-RTU);
Wide voltage design;
LED digital tube display, field parameters can be set;
Dry contact alarm output, normally open / normally closed;
Security, no need to add protective cover.
Realize telemetry, remote signaling and remote adjustment, and realize multiple automatic protection and comprehensive fault self diagnosis function;
Exquisite workmanship and high-quality international famous brand accessories ensure that the products are more stable and reliable;
Multiple protection functions, RS485 interface (MODBUS-RTU);
Wide voltage design;
LED digital tube display, field parameters can be set;
Dry contact alarm output, normally open / normally closed;
Security, no need to add protective cover.
Cooling Capacity | 50W/K | 60W/K | 80W/K | 100W/K | 120W/K | 150W/K | 180W/K | 200W/K | 300W/K |
Rated Power | 68W | 129W | 190W | 190W | 195W | 380W | |||
Width(W)*Depth(D)*Height(H) (Including Flanges) | 546*155*1001(mm) | 546*200*1001(mm) | 569*240*1297(mm) | 671*240*1297(mm) | |||||
Width(W)*Depth(D)*Height(H) (Excluding Flanges) | 495*155*950(mm) | 495*200*950(mm) | 518*240*1246(mm) | 620*240*1246(mm) | |||||
Storage Temperature | -40 ~ +70℃ | -40 ~ +70℃ | |||||||
Working Temperature | -40 ~ +65℃ | -40 ~ +65℃ | |||||||
Heating | \ | \ | |||||||
Input Voltage | -48VDC | -48VDC | |||||||
Mounting Method | Embedded | Embedded | |||||||
IP Grade | IP 55 | IP 55 | |||||||
Air Volume | 450m³/h | 850m³/h | 860m³/h | 950m³/h | 1600m³/h | ||||
Noise | 65 dB(A) | 65 dB(A) | |||||||
Weight | 30 kg | 32 kg | 35 kg | 40 kg | 50 kg | 60 kg |
Cooling Capacity | 50W/K | 60W/K | 80W/K | 100W/K | 120W/K | 150W/K | 180W/K | 200W/K | 300W/K |
Rated Power | 68W | 129W | 190W | 190W | 195W | 380W | |||
Width(W)*Depth(D)*Height(H) (Including Flanges) | 546*155*1001(mm) | 546*200*1001(mm) | 569*240*1297(mm) | 671*240*1297(mm) | |||||
Width(W)*Depth(D)*Height(H) (Excluding Flanges) | 495*155*950(mm) | 495*200*950(mm) | 518*240*1246(mm) | 620*240*1246(mm) | |||||
Storage Temperature | -40 ~ +70℃ | -40 ~ +70℃ | |||||||
Working Temperature | -40 ~ +65℃ | -40 ~ +65℃ | |||||||
Heating | \ | \ | |||||||
Input Voltage | -48VDC | -48VDC | |||||||
Mounting Method | Embedded | Embedded | |||||||
IP Grade | IP 55 | IP 55 | |||||||
Air Volume | 450m³/h | 850m³/h | 860m³/h | 950m³/h | 1600m³/h | ||||
Noise | 65 dB(A) | 65 dB(A) | |||||||
Weight | 30 kg | 32 kg | 35 kg | 40 kg | 50 kg | 60 kg |
Packaging Details:
1. Export Standard Packing;
2. Customized Packing is also available.
Delivery:
20 days later after we receive your deposit.
Packaging Details:
1. Export Standard Packing;
2. Customized Packing is also available.
Delivery:
20 days later after we receive your deposit.