| Availability: | |
|---|---|
| Quantity: | |
LANDKING

Integrated floor-standing indoor installation;

| Cooling capacity L27/L35 | 5,000W (17,000 Btu/h) | 7,500W (25,600 Btu/h) | 7,500W (25,600 Btu/h) | 12,500W (42,660 Btu/h) | 15,000W (51,200 Btu/h) | 20,000W (68,200 Btu/h) | 25,000W (85,300 Btu/h) | 30,000W (102,400 Btu/h) |
| Product mode | LCA050DA | LCA075DA | LCA075DS | LCA125DS | LCA150DS | LCA200DS | LCA250DS | LCA250DS |
| Dimension(W*D*H) | 650*650*1850 | 650*650*1850 | 650*650*1850 | 800*650*1850 | 800*650*1950 | 800*650*2100 | 1000*900*2200 | 1000*900*2200 |
| Mounting method | Indoor-stand/Embed | Indoor-stand/Embed | Indoor-stand/Embed | Indoor-stand/Embed | Indoor-stand/Embed/Side | Indoor-stand/Side | Indoor-stand | Indoor-stand |
| Storage temperature | -40~+70℃ | -40~+70℃ | -40~+70℃ | -40~+70℃ | -40~+70℃ | -40~+70℃ | -40~+70℃ | -40~+70℃ |
| Working temperature | -25~+45℃ | -25~+45℃ | -25~+45℃ | -25~+45℃ | -25~+45℃ | -25~+45℃ | -25~+45℃ | -25~+45℃ |
| Humidity | 27℃ | 27℃ | 27℃ | 27℃ | 27℃ | 27℃ | 27℃ | 27℃ |
| Input voltage | 220V±15% 50Hz | 220V±15% 50Hz | 380V±10% 50Hz | 380V±10% 50Hz | 380V±10% 50Hz | 380V±10% 50Hz | 380V±10% 50Hz | 380V±10% 50Hz |
| Power consumption L27/L35 | 2050W | 3200W | 3200W | 5500W | 6500W | 8500W | 8500W | 8500W |
| Heating | 2000W | 2000W | 2000W | 3000W | 6000W | 9000W | 12000W | 12000W |
| Inner circulation airflow | 3000m³/h | 3000m³/h | 3000m³/h | 4000m³/h | 5500m³/h | 6000m³/h | 8000m³/h | 10000m³/h |
| IP grade | IP 55 | IP 55 | IP 55 | IP 55 | IP 55 | IP 55 | IP 55 | IP 55 |
| Refrigerant | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A |
| Noise | 70dB(A) | 70dB(A) | 70dB(A) | 70dB(A) | 75dB(A) | 75dB(A) | 80dB(A) | 80dB(A) |
| Weight | 210kg | 210kg | 220kg | 260kg | 290kg | 320kg | 400kg | 450kg |
Item feature summary:
It can realize telemetry, remote signaling and remote regulation, multiple automatic protection and comprehensive fault self diagnosis;
Exquisite technology and high quality international famous brand accessories ensure more stable and reliable products;
Suitable for T1 high temperature working condition and R410A environmental protection refrigerant;
Multiple protection function, RS485 interface (MODBUS-RTU);
LCD display, field parameters can be set;
Dry contact alarm output, NO / NC optional.


Fresh air cooling air conditioner is energy-saving, dual mode refrigeration, applicable for data center cooling and telecommunication base station cooling., etc. More details, see computing data center cooling case in Project Cases section.
Aspects in contrast | General split air conditioning
| Free-cooling All-in-one Type Air Conditioning
|
Industrial practicality | Design based on human physiological characteristics; The indoor air flow is less than 1000m3 / h, and the temperature difference between the inlet and outlet air is large;
| Designed based on the working characteristics of electronic components, the temperature difference between the inlet and outlet air is minor, the temperature drops slowly, and the indoor temperature is uniform;
|
Dehumidification, 50% - 70% sensible heat accuracy;
| Light dehumidification, 85% - 95% sensible heat accuracy;
| |
Unable to meet various industrial standards; It is difficult to start in winter in low temperature area;
| Base station dedicated air conditioning, natural cooling function to achieve energy saving, 1 / 3 time in a year can use natural cooling in most areas;
| |
Safety of use | With outdoor machines, not convenient for high-rise maintenance, not safe, not anti-theft; Split structure, refrigerant is easy to leak.
| No outdoor machine, easy to guard against theft, installation and maintenance, refrigerant is not easy to leak;
|
There are many plastic parts in indoor unit, which are easy to produce static electricity;
| The shell of the unit is a metal part, which is not easy to produce static electricity;
| |
Ease of use | No intelligent control system, need daily management;
| Remote monitoring function, Intelligent control, no need for special management;
|
Economy of use | The refrigeration function runs all year round with high cost and fast loss;
| Long working life.
|